فیلترها/جستجو در نتایج    

فیلترها

سال

بانک‌ها




گروه تخصصی











متن کامل


عنوان: 
نویسنده: 

YAMINI Y. | ABDOSSALAMI ASL Y.

اطلاعات دوره: 
  • سال: 

    2016
  • دوره: 

    23
تعامل: 
  • بازدید: 

    179
  • دانلود: 

    0
چکیده: 

SAMPLE PREPARATION HAS A UNIQUE MEANING AND SPECIAL IMPORTANCE IN THE FIELD OF ANALYTICAL CHEMISTRY. FOR SEVERAL DECADES, LIQUID–LIQUID EXTRACTION (LLE) HAS BEEN EMPLOYED FOR SAMPLE PREPARATION PRIOR TO ANALYSIS BY HIGH PERFORMANCE LIQUID CHROMATOGRAPHY AND GAS CHROMATOGRAPHY. RECENT DEVELOPMENTS IN SAMPLE PREPARATION ARE DIRECTED TOWARD DOWN SCALING AND AUTOMATION OF CONVENTIONAL EXTRACTION METHODS BY DECREASING THE ACCEPTOR-TO-DONOR RATIO IN ORDER TO REDUCE ORGANIC SOLVENT, SAMPLE SOLUTION AND CHEMICAL REAGENT CONSUMPTION [1]. ...

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 179

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 0
اطلاعات دوره: 
  • سال: 

    2015
  • دوره: 

    13
تعامل: 
  • بازدید: 

    164
  • دانلود: 

    0
چکیده: 

BACKGROUND AND PURPOSE: THE ABILITY TO PERFORM LABORATORY OPERATIONS ON SMALL SCALES USING MINIATURIZED (NANO LAB-ON-A-CHIP) DEVICES HAS MANY BENEFITS. NANO LAB-ON-A-CHIP TECHNOLOGY ENABLES THE PERFORMANCE OF SEVERAL DIFFERENT EXPERIMENTAL TASKS IN COMBINATION WITH AUTOMATED DATA ANALYSIS IN ONE PROCESS ON A SINGLE INSTRUMENTAL PLATFORM. IN THIS STUDY, WE REVIEW THE ADVANTAGES OF LAB-ON-A-CHIP TECHNOLOGY...

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 164

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 0
نویسندگان: 

نشریه: 

JOURNAL OF NANOPHOTONICS

اطلاعات دوره: 
  • سال: 

    2017
  • دوره: 

    6
  • شماره: 

    1
  • صفحات: 

    123-136
تعامل: 
  • استنادات: 

    1
  • بازدید: 

    156
  • دانلود: 

    0
کلیدواژه: 
چکیده: 

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 156

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 1 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources
اطلاعات دوره: 
  • سال: 

    621
  • دوره: 

    1
  • شماره: 

    2
  • صفحات: 

    39-42
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    18
  • دانلود: 

    0
چکیده: 

Micromixing has a practical application in analyzing of many biochemical and biologicals detection devices of LAB-on-a-CHIP (LOC). The conventional static micromixers require the channel with more lengths and also require times to reach to complete mixing owing to its dependence on transverse diffusion. However, in the electrokinetic micromixers, as the surface properties of the microchannel run the electro-osmotic flow characteristics, surface heterogeneity (non-uniform zeta potentials) can be seen to make vortices or specific flow structures for better mixing performance. This study aims to use computational fluid dynamics (CFD) to numerically compare the concentration rate of the various electrokinetic micromixers in in the presence of the electric conductor. The results revealed that the off-center microchannel design in a micromixer can augment the rate of concentration. In addition, circular microchannel design showed better mixing compared to the triangular and square designs. These results are useful not only for understanding of the profiles of concentration in the electrokinetic micromixers, but also for providing a comprehensive information on the design of the microchannels, which may result in better mixture in the fluids

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 18

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
اطلاعات دوره: 
  • سال: 

    1398
  • دوره: 

    9
  • شماره: 

    2
  • صفحات: 

    1346-1356
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    1430
  • دانلود: 

    12
چکیده: 

پیشرفت های اخیر در دانش و فناوری سبب شده است تا شاهد انقلاب در بسیاری از حوزه های مختلف علمی و صنعتی باشیم. اصطلاح آزمایشگاه در یک تراشه یا به عبارت دیگر انجام انواع آنالیزهای پیچیده تنها در مدت زمان اندک و در یک فضای بسیار کوچک اصطلاحی است که در سال های اخیر بسیار رایج گردیده و آنچه درگذشته به عنوان یک آرزو مطرح بوده اکنون به صورت عملی و واقعی وارد زندگی نوع بشر شده است. در این مقاله تلاش گردیده تا نوع خاصی از فناوری آزمایشگاه بر روی یک تراشه که البته یکی از رایج ترین آن ها نیز هست، یعنی دانش و فناوری میکروسیال (میکروکانال) موردبحث و بررسی قرار گیرد. گستره وسیع کاربرد این فناوری سبب گردیده است تا استفاده از آن به سرعت عملی گردد. هرچند گستره ی این فناوری بسیار وسیع است و در بسیاری از شاخه های علم و صنعت وارد گردیده اما در اینجا تنها کاربردهای این فناوری در حوزه های تشخیصی در پزشکی و بیولوژی موردتوجه قرار گرفته است. در این مقاله به خصوص به بررسی دستگاه های ساخته شده با فناوری میکروسیال برای آنالیز DNA، دستگاه های تشخیصی بر اساس جداسازی، دستگاه ها برای بررسی، مرتب کردن و آنالیز عمومی سلول ها و دستگاه های مبتی بر اساس پروتئین موردبحث و بررسی قرار گرفته است.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 1430

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 12 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 5
نشریه: 

BioImpacts

اطلاعات دوره: 
  • سال: 

    2024
  • دوره: 

    14
  • شماره: 

    4
  • صفحات: 

    1-8
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    22
  • دانلود: 

    0
چکیده: 

Introduction: The microfluidic device is highly optimized to remove oocytes from the cumulus-corona cell mass surrounding them. Additionally, it effectively captures and immobilizes the oocytes, aiding in assessing their quality and facilitating the injection of sperm into the oocyte. In this study, a novel microfluidic CHIP was designed and manufactured using conventional soft lithography methods. Methods: This research proposes the utilization of a microfluidic CHIP as a substitute for the conventional manual procedures involved in oocyte denudation, trapping, and immobilization. The microfluidic CHIP was modeled and simulated using COMSOL Multiphysics® 5. 2 software to optimize and enhance its design and performance. The microfluidic CHIP was fabricated using conventional injection molding techniques on a polydimethylsiloxane substrate by employing soft lithography methods. Results: A hydrostatic force was applied to guide the oocyte through predetermined pathways to eliminate the cumulus cells surrounding the oocyte. The oocyte was subsequently confined within the designated trap region by utilizing hydraulic resistance along the paths and immobilized by applying vacuum force. Conclusion: The application of this CHIP necessitates a lower level of operator expertise compared to enzymatic and mechanical techniques. Moreover, it is feasible to continuously monitor the oocyte's state throughout the procedure. There is a reduced need for cultural media compared to more standard approaches.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 22

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 4
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources
اطلاعات دوره: 
  • سال: 

    1401
  • دوره: 

    52
  • شماره: 

    3
  • صفحات: 

    189-194
تعامل: 
  • استنادات: 

    1
  • بازدید: 

    127
  • دانلود: 

    38
چکیده: 

Intracytoplasmic sperm injection (ICSI) is one of the most successful techniques of Assisted Reproductive Technology (ART) and is mostly in use for the treatment of infertility with male factors. In this method, before injecting sperm into the intracytoplasmic of the oocyte, cumulus cells around the oocyte must be stripped to facilitate the injection process. To achieve this, both enzymatic and mechanical methods are used in embryological LABoratories for denudation, which has major deficiencies, including the possibility of damaging the oocyte prior to the injection process. In this research, a microfluidic-based device is introduced for the separation of cumulus cells around the oocyte with minimum manual operations. The results prove high efficiency, and non-destructive denudation of the oocyte with the reduced amount of culture medium leads to the low-cost preparation process of oocytes. The process can also be integrated with ICSI CHIPs under development and will be reported shortly.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 127

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 38 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 1 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
نویسندگان: 

اطلاعات دوره: 
  • سال: 

    2020
  • دوره: 

    13
  • شماره: 

    4
  • صفحات: 

    313-329
تعامل: 
  • استنادات: 

    1
  • بازدید: 

    42
  • دانلود: 

    0
کلیدواژه: 
چکیده: 

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 42

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 1 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
اطلاعات دوره: 
  • سال: 

    1397
  • دوره: 

    18
  • شماره: 

    1
  • صفحات: 

    239-246
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    679
  • دانلود: 

    326
چکیده: 

لطفا برای مشاهده چکیده به متن کامل (PDF) مراجعه فرمایید.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 679

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 326 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
اطلاعات دوره: 
  • سال: 

    1398
  • دوره: 

    10
  • شماره: 

    2
  • صفحات: 

    51-58
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    681
  • دانلود: 

    153
چکیده: 

این مقاله به کوچک سازی سنسور C4D برای سیستم های آزمایشگاهی بر روی تراشه(LOC) و چگونگی تاثیر پارامترهای آن نظیر جنس تراشه، بار یونی و فرکانس و هندسه الکترودها بر روی آن از طریق نرم افزار کامسول می پردازد. نتایج نشان می دهند هنگامی که جنس تراشه از شیشه باشد، چگالی جریان در زمان حضور یون به A/m2003/0 افزایش می یابد و تراشه ای از جنس پلی دی متیل سیلوکسان این چگالی را به A/m2 0015/0 می رساند. با بکارگیری ترکیبی از این دو ماده علاوه بر دستیابی به مزایای پلی دی متیل سیلوکسان، حساسیت حسگر نیز افزایش می یابد. افزون بر این، افزایش فرکانس ورودی مانع از هر گونه تغییر چگالی ناگهانی جریان می شود و تغییر بار یونی از 1 تا 5، منجر به تغییر هدایت الکتریکی از S/m 7-10 تا S/m 7-10 × 8 می گردد. طراحی تراشه با چهار الکترود نیز به دلیل شدت جریان بالاتر در بدنه محلول، حساسیت حسگر را افزایش می دهد. انتخاب مناسب سنسور C4D بر روی تراشه با حساسیت بالا می-تواند در آینده زمینه ساز بسیاری از پیشرفت ها در زمینه پزشکی و تشخیص طبی باشد.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 681

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 153 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
litScript
telegram sharing button
whatsapp sharing button
linkedin sharing button
twitter sharing button
email sharing button
email sharing button
email sharing button
sharethis sharing button